Norwegian Star

Norwegian Cruise Lines · CDC Vessel Sanitation Program record

Satisfactory: score 99 out of 100

Latest inspection December 5, 2025 · CDC inspection report

CDC’s passing mark is 86 out of 100.

Cruise line
Norwegian Cruise Lines
Inspections in this snapshot
36
Currently on the Green Sheet
Yes

Score history

Dates and scores are as CDC's inspection search returned them. Failing scores are shaded. Each report link goes to the official CDC page.

Score history for Norwegian Star

Inspection dateScore and official resultCDC report
December 5, 202599 SatisfactoryOfficial report
August 7, 2025100 SatisfactoryOfficial report
July 13, 202498 SatisfactoryOfficial report
November 19, 201894 SatisfactoryOfficial report
January 19, 201895 SatisfactoryOfficial report
March 13, 201694 SatisfactoryOfficial report
October 19, 201594 SatisfactoryOfficial report
April 5, 201591 SatisfactoryOfficial report
October 20, 201491 SatisfactoryOfficial report
April 25, 201495 SatisfactoryOfficial report
February 16, 201482 Not satisfactoryOfficial report
October 13, 201394 SatisfactoryOfficial report
April 23, 201389 SatisfactoryOfficial report
October 25, 201299 SatisfactoryOfficial report
July 8, 201297 SatisfactoryOfficial report
January 29, 201298 SatisfactoryOfficial report
August 20, 201199 SatisfactoryOfficial report
February 5, 201194 SatisfactoryOfficial report
September 15, 201099 SatisfactoryOfficial report
March 6, 201099 SatisfactoryOfficial report
September 26, 200999 SatisfactoryOfficial report
February 21, 200998 SatisfactoryOfficial report
August 21, 200898 SatisfactoryOfficial report
February 4, 200894 SatisfactoryOfficial report
August 18, 200797 SatisfactoryOfficial report
November 6, 200694 SatisfactoryOfficial report
July 18, 200699 SatisfactoryOfficial report
January 28, 200699 SatisfactoryOfficial report
July 12, 200598 SatisfactoryOfficial report
October 28, 200499 SatisfactoryOfficial report
March 21, 200499 SatisfactoryOfficial report
October 17, 200395 SatisfactoryOfficial report
April 13, 200396 SatisfactoryOfficial report
October 20, 2002100 SatisfactoryOfficial report
April 7, 200295 SatisfactoryOfficial report
December 16, 200197 SatisfactoryOfficial report

Latest official findings

The official report lists the following findings. The wording is quoted from CDC, grouped by the area of the ship so it is easier to read. We do not change the inspector's wording.

Drinking water (1 finding)

Item 08

Where it was found: Potable Water-Deck 5- Fan Room 5-5-056

Official finding: The potable water line used for washing the fan units was not striped blue or blue/green/blue. This was corrected before the end of the inspection.

Official recommendation

Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate water lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines, including potable water supply lines in technical lockers, at 5-meters (16.4 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water. Identify all refrigerant brine lines and nonpotable chilled water lines in all food areas, such as on ice machines, ice cream machines, etc., with either ISO 14726 (blue/white/blue) or by another uniquely identifiable method to prevent cross-connections.

Galleys and dining rooms (20 findings)

Item 27

Where it was found: Galley-Acute Gastroenteritis (AGE) Log

Official finding: Condensate collected inside the exhaust hood overhang above the soiled side of the dishwash machine and dripped onto the portable cart. Condensate was also on the air supply vent at the middle of the machine and on the deckhead at the emergency exit sign.

Official recommendation

Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.

Item 33

Where it was found: Provisions-Deck 3 - Pastry Freezer

Official finding: The deck in the back of the room was soiled with a red liquid.

Official recommendation

Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.

Item 33

Where it was found: Provisions-Deck 4 - Cold Room/Eggs

Official finding: The deck was soiled with a brown liquid in multiple areas of the room.

Official recommendation

Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.

Item 19

Where it was found: Provisions-Deck 4 - Cold Room/Eggs

Official finding: A box of masago orange was wet. The plastic food containers inside the box were not impacted.

Official recommendation

Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; (4) At least 150 millimeters (6 inches) above the deck; (5) At least 127 millimeters (5 inches) for food in packages and working containers on pallets, skids, and racks; (6) At least 150 millimeters (6 inches) above the deck on shelving units.

Item 20

Where it was found: Preparation Room-Deck 4 - Bakery / Pastry

Official finding: The counter-mounted mixer had been out of service since 24 October 2025.

Official recommendation

Maintain food-contact equipment in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these standards; (2) Can opener parts that cut or pierce must be kept sharp to minimize the creation of metal fragments that can contaminate food when the container is opened.

Item 33

Where it was found: Preparation Room-Deck 3 - Potwash

Official finding: A green hose was stored on the deck below the potwash machine, making cleaning the deck difficult.

Official recommendation

Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.

Item 36

Where it was found: Preparation Room-Deck 4 - Meat Room

Official finding: The light intensity measured less than 220 lux at the handwashing station near the entrance.

Official recommendation

Ensure the light intensity is at least 220 lux (20 foot-candles) on food preparation surfaces. Ensure the light intensity is at least 220 lux (20 foot-candles) as measured 750 millimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment and utensil storage, pantries, toilet rooms, and consumer self-service areas.

Item 20

Where it was found: Preparation Room-Deck 4 - Poultry Thawing Room

Official finding: The temperature gauge inside the walk-in refrigerator read 50°F. A work order was placed on the morning of the inspection stating the temperature was too high. All foods in the room were within proper temperature.

Official recommendation

Maintain food-contact equipment in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these standards; (2) Can opener parts that cut or pierce must be kept sharp to minimize the creation of metal fragments that can contaminate food when the container is opened. Ensure equipment for cooling and heating food and holding cold and hot food is sufficient in number and capacity to maintain temperatures in TCS/PHF.

Item 33

Where it was found: Preparation Room-Deck 4 - Poultry Thawing Room

Official finding: The deck was soiled below the evaporator condenser with a red liquid.

Official recommendation

Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.

Item 33

Where it was found: Galley-Deck 6 - Warewash Area

Official finding: Condensate collected inside the exhaust hood overhang above the soiled side of the dishwash machine and dripped onto the portable cart. Condensate was also on the air supply vent at the middle of the machine and on the deckhead at the emergency exit sign.

Official recommendation

Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.

Item 21

Where it was found: Galley-Deck 6 - Aqua Hot Galley

Official finding: Water leaked from the steam line inside the bain marie technical compartment #2.

Official recommendation

Maintain nonfood-contact equipment in good repair and proper adjustment including: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these standards; (2) Equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact and tight and adjusted in accordance with manufacturer's specifications.

Item 33

Where it was found: Food Service General-Condition of Decks

Official finding: Numerous deck tiles were cracked throughout the galley. A technician was replacing tiles during the inspection.

Official recommendation

Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.

Item 22

Where it was found: Galley-Deck 5

Official finding: The glasswash machine had been out of service since the morning of the inspection. The final rinse was not working.

Official recommendation

Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.

Item 33

Where it was found: Galley-Deck 5

Official finding: Condensate collected inside the exhaust hood overhang above the soiled side of the dishwash machine.

Official recommendation

Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.

Item 37

Where it was found: Galley-Deck 5

Official finding: Condensate collected inside the exhaust hood overhang above the soiled side of the dishwash machine.

Official recommendation

Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensate from collecting on bulkheads and deckheads.

Item 37

Where it was found: Galley-Deck 6 - Warewash Area

Official finding: Condensate was inside the exhaust hood overhang above the soiled side of the dishwash machine and dripped onto the portable cart. Condensate was also on the air supply vent at the middle of the machine and on the deckhead at the emergency exit sign.

Official recommendation

Ensure ventilation hood systems and devices operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and to remove contaminants generated by equipment located under them. Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensate from collecting on bulkheads and deckheads.

Item 22

Where it was found: Galley-Deck 5 - Potwash

Official finding: Dried food soil accumulated along the inside ledge of the hood-type potwash machine door.

Official recommendation

Ensure warewashing machines, drainboards, and the compartments of sinks, basins, or other receptacles used for washing and rinsing equipment, utensils, or raw food, or laundering wiping cloths are cleaned: (1) Before use; (2) Throughout the day at a frequency necessary to prevent recontamination and accumulation of debris and to ensure the equipment performs its intended function; (3) At least every 24 hours (if used).

Item 26

Where it was found: Buffet-Deck 5 - Crew Mess

Official finding: The ice/water dispenser's ice chute was soiled with a brown residue.

Official recommendation

Ensure food only contacts surfaces of cleaned and sanitized equipment and utensils. Ensure food-contact surfaces of equipment and utensils are clean to sight and touch.

Item 20

Where it was found: Buffet-Deck 5 - Crew Mess

Official finding: One plastic gray silverware container was cracked in two areas making the containers difficult to clean.

Official recommendation

Materials used in the construction of multiuse utensils and food-contact surfaces of equipment must be: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.

Item 21

Where it was found: Galley-Deck 7 - O'Sheehan's

Official finding: The support plates between the two-stack oven were not secured and had a gap between the plates and the bottom oven.

Official recommendation

Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.

Medical center (1 finding)

Item 11

Where it was found: Medical-Acute Gastroenteritis (AGE) Log

Official finding: Two nonfood employees reported to medical several hours after AGE symptom onset. Both received disciplinary action and retraining. One nonfood employee experienced symptoms on 15 November at 1200 and reported to medical at 1700. According to documentation, the crew member did not work but visited crew mess at 1200. A second nonfood employee experienced symptoms on 17 November at 1600 and reported to medical at 1954. The crew member visited staff mess at 1730 and worked from 1600-1800.

Official recommendation

When nonfood employees are symptomatic and meet the case definition for AGE, ensure the following actions are taken: (1) Isolate in cabin or designated restricted area until symptom-free for a minimum of 24 hours; (2) Follow-up with and receive approval by designated medical personnel before returning crew to work; (3) Document the date and time of last symptom and clearance to return to work.

Other inspection items (1 finding)

Item 24

Where it was found: Bar-Deck 7 - Atrium Cafe

Official finding: The container of sanitizing solution measured less than 50 ppm at the espresso machine.

Official recommendation

Ensure sanitizing solutions are used with the following concentrations: (1) A chlorine solution with a concentration between 50 mg/L (ppm) and 200 mg/L (ppm); (2) An iodine solution with a pH of 5.0 or less or a pH no higher than the level for which the manufacturer specifies the solution is effective AND a concentration between 12.5 mg/L (ppm) and 25 mg/L (ppm); (3) A quaternary ammonium compound solution with a concentration as specified in 40 CFR 180.940 Sanitizing Solutions AND as indicated by the manufacturer’s use directions included in the labeling. If another solution concentration or pH of a chlorine, iodine, or quaternary ammonium compound is used, demonstrate to VSP that the solution achieves sanitization and the use of the solution is approved. If a chemical sanitizer other than a chlorine, iodine, or quaternary ammonium compound is used, ensure it is applied in accordance with the manufacturer’s use directions included in the labeling.

Gastrointestinal outbreak notices

These are official CDC Vessel Sanitation Program outbreak postings for this ship, not inspection scores. CDC generally posts a voyage when 3% or more of passengers or crew report gastrointestinal illness, or when an outbreak is otherwise of public health significance.

Official outbreak notices collected for this ship

Sailing datesCausative agentCase countsSource
1/5/2014-1/19/2014NorovirusPassengers: 130 of 2,318 (5.61%). Crew: 12 of 1,039 (1.15%).CDC notice
1/19/2008-1/27/2008NorovirusPassengers: 228 of 2,427 (9.39%). Crew: 32 of 1,103 (2.9%).CDC notice
5/19/2007-5/26/2007NorovirusPassengers: 177 of 2,331 (7.59%). Crew: 7 of 1,100 (0.65%).CDC notice
5/14/2006-5/21/2006NorovirusPassengers: 115 of 2,388 (4.82%). Crew: 12 of 1,063 (1.13%).CDC notice
9/21/2003-9/28/2003Specimens not obtainedPassengers: Data not available. Crew: Data not available.CDC notice

Source: CDC Vessel Sanitation Program. This page does not change the substantive content of official scores or findings.