The official report lists the following findings. The wording is quoted from CDC, grouped by the area of the ship so it is easier to read. We do not change the inspector's wording.
Drinking water (1 finding)
Item 08
Where it was found: Potable Water-Tank Coating
Official finding: There was no written documentation of approval from a certification organization for the potable water tank coating.
Official recommendation
Ensure the interior coatings on potable water tanks are approved for potable water contact by a certification organization. Follow all manufacturers? recommendations for application, drying, and curing. For the tank coatings used, maintain the following onboard: (1) written documentation of approval from the certification organization (independent of the coating manufacturer); (2) manufacturers? recommendations for application, drying, and curing; and (3) written documentation that the manufacturers? recommendations have been followed for application, drying, and curing.
Galleys and dining rooms (7 findings)
Item 39
Where it was found: Food Service General-Flies
Official finding: Small flies were seen in the following areas on the lounge deck:
One was by the beverage station.
Two were at the bar.
Two were at the pulper in the main galley.
One was at the handwashing station near the pulper in the main galley.
Official recommendation
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item 33
Where it was found: Galley-Walk-in Refrigerator
Official finding: The sealant was peeling between two deckhead panels.
Official recommendation
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item 08
Where it was found: Galley-Combination Ovens
Official finding: The backflow prevention device was not easily accessible for inspection.
Official recommendation
Ensure backflow prevention devices and air gaps are accessible for inspection, testing, service, and maintenance. If access panels are required, ensure panels are large enough for testing, service, and maintenance.
Item 22
Where it was found: Galley-Dishwash
Official finding: A water leak was below the rack-type dishwash machine's final sanitizing rinse compartment.
Official recommendation
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines.
Item 28
Where it was found: Galley-Reach-in Refrigerator
Official finding: Three foldable food storage containers were stored on the deck beside the reach-in refrigerator.
Official recommendation
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck unless in packages on pallets, skids, or racks, which may be 127 millimeters (5 inches).
Item 20
Where it was found: Dining Room-Beverage Station
Official finding: The coffee dispenser had slotted fasteners in the food splash area.
Official recommendation
Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item 21
Where it was found: Dining Room-Buffet Line
Official finding: An open seam was on the hot plate/countertop juncture.
Official recommendation
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Housekeeping (2 findings)
Item 41
Where it was found: Housekeeping-Disinfectant Test Strips
Official finding: The test strips were not appropriate for the disinfectant used onboard during outbreaks. When the staff member applied the disinfectant to the test strip, it turned green which is not on the color comparator.
Official recommendation
Ensure appropriate test strips are used to effectively measure the disinfectant's concentration.
Item 41
Where it was found: Housekeeping-Outbreak Prevention and Response Plan (OPRP)
Official finding: The OPRP did not include the concentration for the disinfectant used during outbreaks.
Official recommendation
Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: Disinfectant products or systems used, including the surfaces or items the disinfectants will be applied to, concentrations, and required contact times. Ensure the disinfectant products or systems are effective against human norovirus or an acceptable surrogate (e.g., caliciviruses).
Other inspection items (1 finding)
Item 20
Where it was found: Bar-Lounge Deck
Official finding: The soda gun had slotted fasteners on the food contact area.
Official recommendation
Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Gastrointestinal outbreak notices
No official CDC outbreak notice in the listings we collected is clearly matched to this ship. That is not a guarantee that no illness occurred; it only means none of the posted notices we have were matched here. See the outbreak list.
Source: CDC Vessel Sanitation Program. This page does not change the substantive content of official scores or findings.