The official report lists the following findings. The wording is quoted from CDC, grouped by the area of the ship so it is easier to read. We do not change the inspector's wording.
Drinking water (1 finding)
Item 06
Where it was found: Potable Water-Legionella Testing
Official finding: The sampling locations did not include enough samples from the galley to be representative of the ship.
Official recommendation
The Legionella sampling plan must include a selection of the following locations: (4) Representative points of use in cabins, galleys, and recreational areas. Include a mix of fixture types (showers, sink faucets, tubs). Include potable water samples when temperatures are in the range favorable for Legionella growth (77°–113°F, 25°–45°C).
Galleys and dining rooms (19 findings)
Item 16
Where it was found: Buffet-Deck 14- Oceanview Cafe Pasta Station
Official finding: A pan of cooked spaghetti was in an undercounter drawer in time control unit F with no discard label. The area was open for more than 4 hours. A discard label was placed on the pan.
Official recommendation
If time without temperature control is used as the public health control with a maximum of 4 hours, ensure the food (1) Has an initial temperature of 5°C (41°F) or less or 57°C (135°F) or greater before placement on time control; (a) Food may have an initial temperature of 21°C (70°F) or less before placement on time control if it is a ready-to-eat fruit or vegetable that becomes a TCS/PHF after cutting OR it is a ready-to-eat hermetically sealed food that becomes a TCS/PHF after opening AND (i) The food temperature does not exceed 21°C (70°F) within 4 hours from the time it became a TCS/PHF; (ii) The food is marked or otherwise identified to indicate 4 hours past the time it became a TCS/PHF (regardless of whether the time between service setup and closing exceeds 4 hours). (2) Is not to be placed on temperature control again; (3) Is marked or otherwise identified to indicate the time 4 hours past the time when the food is removed from temperature control if the time between service setup and closing is greater than 4 hours; (a) If time control unit meant to be cold holding or hot holding is not operational or used as intended, the unit is considered a counter, and the food stored within it must be labeled with its 4-hour discard time; (b) Containers of TCS/PHF under time control and placed on preparation counters must be labeled with the discard time, even if the outlet is open less than 4 hours. (4) Is discarded within 4 hours of placement on time control.
Item 39
Where it was found: Buffet-Deck 14- Oceanview Cafe Pastry/Bakery
Official finding: Three fruit flies were near refrigerator #5. The pest manager was called.
Official recommendation
Effectively control the presence of insects, rodents, and other pests to minimize their presence in food areas.
Item 38
Where it was found: Buffet-Deck 14- Oceanview Cafe Bussing Station #1
Official finding: One wet mop was stored in a manner that did not allow air drying. No active cleaning was taking place.
Official recommendation
After use, ensure mops are placed in a position that allows them to air dry without soiling walls, equipment, or supplies.
Item 20
Where it was found: Buffet-Deck 14- Oceanview Cafe Portside Coffee Station
Official finding: The sealant covering a slotted fastener in the coffee dispenser's food splash zone was falling off. The sealant was replaced.
Official recommendation
Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; (5) Accessible for cleaning and inspection by one of the following methods: without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel.
Use low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item 19
Where it was found: Galley-Deck 14- Oceanview Cafe Pantry
Official finding: A large container of salt stored on the countertop was not labeled with the common name of the food. This was corrected.
Official recommendation
Ensure containers holding food or food ingredients removed from their original packages for use on the vessel, such as cooking oils, flour, herbs, potato flakes, salt, spices, and sugar are identified with the common name of the food.
Item 17
Where it was found: Galley-Deck 14- Oceanview Cafe Pantry
Official finding: A pan of raw ground beef meatballs used to make scotch eggs was removed from temperature control and placed on time control plan before time control for the area started. At 1509, a crew member was preparing raw ground beef meatballs used to make scotch eggs. The pan of meatballs was labeled with a set up time of 1500 and a discard time of 1700. According to the time control plan posted for the area, time control began at 1515.
Official recommendation
Maintain a written time control plan that ensures compliance with these standards on the vessel and make it available for review during inspections. Ensure a time control plan is posted and available to all crew working at each outlet where time control is used. Ensure plan(s): (1) Include set-up and discard times for each outlet. Include all services and events where TCS/PHF is kept on time control. If used, ensure colored labels correspond to the discard times stated in the plan; (2) List all units (to include refrigeration and hot holding units, preparation counters, cabinets, compartments, and equipment) on time control. Cabinets and compartments on time control must be physically labeled; (3) Describe or show the flow of TCS/PHF from when last in temperature control to placement in time control and discard.
Item 22
Where it was found: Galley-Deck 14- Oceanview Cafe Flight-type Warewash Machine
Official finding: Two pieces of sliced lemon, a butter wrapper, and a piece of diced chicken were on the clean side of the warewash machine below the conveyor. The machine was cleaned.
Official recommendation
Ensure warewashing machines, drainboards, and the compartments of sinks, basins, or other receptacles used for washing and rinsing equipment, utensils, or raw food, or laundering wiping cloths are cleaned: (1) Before use; (2) Throughout the day at a frequency necessary to prevent recontamination and accumulation of debris and to ensure the equipment performs its intended function; (3) At least every 24 hours (if used).
Item 20
Where it was found: Galley-Deck 14- Oceanview Cafe Spa Cafe
Official finding: The maximum temperature registering thermometer initially used to measure the temperature of the hood-type glasswash machine was not in calibration. When measuring final rinse plate surface temperatures, the thermometer measured 216°F, 217°F, and 220°F. The inspector's thermocouple consistently measured 161°F at the plate surface during the final rinse cycle, and the gauge read 190°F. The thermometer was replaced with a new one.
Official recommendation
Maintain utensils and temperature-measuring devices in good repair and proper adjustment: (1) Utensils must be maintained in a state of repair or condition that meets the materials, design, and construction specifications of these standards or must be discarded; (2) Food temperature-measuring devices must be calibrated in accordance with the manufacturer's specifications as necessary to ensure accuracy.
Item 08
Where it was found: Galley-Deck 16: Retreat Sundeck Pantry
Official finding: No backflow prevention device was on the potable water line used to flush the stagnant line for a removed piece of equipment. The hose extended into the utility sink below the flood rim, creating an indirect connection.
Official recommendation
Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (1) RWFs; (2) Decorative water features/fountains; (3) Cabin shower hoses, toilets, jetted tubs, and similar facilities; (4) Photographic laboratory developing machines and utility sinks; (5) Beauty and barber shop spray-rinse hoses; (6) Spa steam generators where essential oils can be added; (7) Hose-bib connections; (8) Garbage grinders and food waste systems; (9) Automatic galley hood washing systems; (10) Food service equipment; (11) Mechanical warewashing machines; (12) Detergent dispensers; (13) Hospital and laundry equipment; (14) Air conditioning expansion tanks; (15) Boiler feed water tanks; (16) Fire system; (17) Public toilets, urinals, and shower hoses; (18) Potable water, bilge, and pumps that require priming; (19) Freshwater or saltwater ballast systems; (20) International fire and fire sprinkler water connections (install a reduced pressure assembly); (21) Potable water supply to automatic window washing systems that can be used with chemicals or chemical mix tanks; (22) Water softeners for nonpotable fresh water; (23) Water softener and mineralizer drain lines, including backwash drain lines (install an air gap or a reduced pressure assembly); (24) High saline discharge line from evaporators (install an air gap or a reduced pressure assembly); (25) Chemical tanks; (26) Other connections between the potable water system and a nonpotable water system, such as the gray water system, laundry system, or technical water system (install an air gap or a reduced pressure assembly); (27) Black water or combined gray water/black water systems (install an air gap); (28) Hi-Fog or similar suppression systems connected to potable water tanks; (29) Any other connection to the potable water system where contamination or backflow can occur.
Item 08
Where it was found: Galley-Deck 12: Luminae
Official finding: No backflow prevention device was on the potable water line used to flush the stagnant line for a removed piece of equipment. The hose extended into the utility sink below the flood rim, creating an indirect connection.
Official recommendation
Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (1) RWFs; (2) Decorative water features/fountains; (3) Cabin shower hoses, toilets, jetted tubs, and similar facilities; (4) Photographic laboratory developing machines and utility sinks; (5) Beauty and barber shop spray-rinse hoses; (6) Spa steam generators where essential oils can be added; (7) Hose-bib connections; (8) Garbage grinders and food waste systems; (9) Automatic galley hood washing systems; (10) Food service equipment; (11) Mechanical warewashing machines; (12) Detergent dispensers; (13) Hospital and laundry equipment; (14) Air conditioning expansion tanks; (15) Boiler feed water tanks; (16) Fire system; (17) Public toilets, urinals, and shower hoses; (18) Potable water, bilge, and pumps that require priming; (19) Freshwater or saltwater ballast systems; (20) International fire and fire sprinkler water connections (install a reduced pressure assembly); (21) Potable water supply to automatic window washing systems that can be used with chemicals or chemical mix tanks; (22) Water softeners for nonpotable fresh water; (23) Water softener and mineralizer drain lines, including backwash drain lines (install an air gap or a reduced pressure assembly); (24) High saline discharge line from evaporators (install an air gap or a reduced pressure assembly); (25) Chemical tanks; (26) Other connections between the potable water system and a nonpotable water system, such as the gray water system, laundry system, or technical water system (install an air gap or a reduced pressure assembly); (27) Black water or combined gray water/black water systems (install an air gap); (28) Hi-Fog or similar suppression systems connected to potable water tanks; (29) Any other connection to the potable water system where contamination or backflow can occur.
Item 17
Where it was found: Buffet-Deck 15: Retreat Lounge
Official finding: Milk in the espresso machine's milk compartment was placed on time control before time control began for the area. The inspection team was in the area at 1618. The milk had a set up time of 1610 and a discard time of 2010. According to the time control plan, milk in the espresso machine would be on time control from 1130-1530 and 1630-2030. The milk was discarded, and the time control plan was modified to meet the operational needs of the area.
Official recommendation
Maintain a written time control plan that ensures compliance with these standards on the vessel and make it available for review during inspections. Ensure a time control plan is posted and available to all crew working at each outlet where time control is used. Ensure plan(s): (1) Include set-up and discard times for each outlet. Include all services and events where TCS/PHF is kept on time control. If used, ensure colored labels correspond to the discard times stated in the plan; (2) List all units (to include refrigeration and hot holding units, preparation counters, cabinets, compartments, and equipment) on time control. Cabinets and compartments on time control must be physically labeled; (3) Describe or show the flow of TCS/PHF from when last in temperature control to placement in time control and discard.
Item 33
Where it was found: Provisions-Deck 2 - Dry Store
Official finding: A pile of yellow grain food debris was on the deck below a pallet of flour on the right side of the room. Additionally, old food debris was below a pallet of rice on the right side of the room. This was cleaned immediately.
Official recommendation
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item 19
Where it was found: Provisions-Deck 2 - Cheese Room
Official finding: Water collected on a box of shredded mozzarella from the deckhead hatch above. The box of cheese was discarded.
Official recommendation
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination.
Item 33
Where it was found: Provisions-Deck 2 - Cheese Room
Official finding: Condensate formed on the deckhead hatch, which dripped and water pooled on a cardboard box of shredded mozzarella.
Official recommendation
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item 19
Where it was found: Provisions-Deck 2 - General Frozen
Official finding: More than a day's accumulation of ice was on a cardboard box of frozen sweet potatoes. The cardboard box of sweet potatoes was discarded.
Official recommendation
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination.
Item 33
Where it was found: Provisions-Deck 2 - General Frozen
Official finding: More than a day's accumulation of ice was on the deckhead hatch to the right of the evaporator condensing unit in the back right of the room. Additionally, more than a day's worth of ice accumulated to the right of the entrance door.
Official recommendation
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item 19
Where it was found: Provisions-Deck 2 - Frozen Fish
Official finding: More than a day's accumulation of ice formed on a cardboard box of frozen fish. The cardboard box was discarded.
Official recommendation
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination.
Item 33
Where it was found: Provisions-Deck 2 - Frozen Fish
Official finding: More than a day's accumulation of ice formed on the deckhead to the left of the evaporator condensing unit.
Official recommendation
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item 23
Where it was found: Galley-Deck 14- Oceanview Cafe Flight-type Warewashing Machine
Official finding: Two pieces of sliced lemon, a butter wrapper, and a piece of diced chicken were on the clean side of the warewash machine below the conveyor. The machine was cleaned.
Official recommendation
Ensure food debris on equipment and utensils is scrapped over a waste disposal unit, pulper, or garbage receptacle or removed in a warewashing machine with a prewash cycle.
Gastrointestinal outbreak notices
No official CDC outbreak notice in the listings we collected is clearly matched to this ship. That is not a guarantee that no illness occurred; it only means none of the posted notices we have were matched here. See the outbreak list.
Source: CDC Vessel Sanitation Program. This page does not change the substantive content of official scores or findings.